| Peer-Reviewed

Case Study of The Relationship between Heat-Resistant Paint and Comfortable Indoor Temperatures

Received: 10 September 2014     Accepted: 7 October 2014     Published: 20 October 2014
Views:       Downloads:
Abstract

Higher temperatures can cause health problems such as heat stroke, and the number of cases increases sharply in people over 65 years old. Elderly people have a high risk of heat stroke, not only during the day but also at night, and they also have a reduced sensitivity to heat, so the possibility that countermeasures are taken too late increases. In such cases adverse effects cannot be prevented by measures involving voluntary action, including the provision of air conditioning. For these reasons, heat stroke countermeasures involving methods that do not depend on the sensory functions of the target person are needed. Therefore, we propose a new method for controlling indoor temperatures using heat-resistant paint. In this study, two verification experiments were conducted totest the proposed temperature control method in cargo containers and communal buildings. The effectiveness of the methods was apparent in measurements of temperature and electricity consumption.

Published in International Journal of Environmental Protection and Policy (Volume 2, Issue 5)
DOI 10.11648/j.ijepp.20140205.17
Page(s) 185-189
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2014. Published by Science Publishing Group

Keywords

Heat-Resistant Paint, Temperature Control, Energy Saving

References
[1] Ilmarinen. J, Tuomi. K, Eskelinen. L, Nygard. C-H, Huuhtanen. P & Klockars., Background and objectives of the finish research project on aging workers in municipal occupations, Second. J. Work Environ. Health, Vol.17, Supplement 1, 1981, pp.7-11.
[2] Kawakami. M & Kajihara. Y (2001), A model for activating the elderly in the production system, Proc. of NES2001, 2001, pp.359-363.
[3] Seisamo. J & Ilmarinen. J (1997), Life-Style aging and work ability among active finish workers in 1981-1992, Second. J. Work Environ. Health, Vol.23, Supplement 1, 1997, pp.20-26.
[4] Nygard. C-H, Huuhtanen. P, Tuomi. K & Martikainen. R, Perceived work changes between 1981 and 1992 among aging workers in Finland, Second. J. Work Environ. Health, Vol.23, Supplement 1, 1997, pp.12-19.
[5] Haermae. M & Ilmarinen. J, Towards the 24-hour Society-New Approaches for Aging Shift Workers?, Second. J. Work Environ. Health, Vol.25, No.6, 1999, pp.610-615.
[6] Huuhtanen. P, The aging worker in a changing work environment, Second. J. Work Environ. Health, Vol.14, Supplement 1, 1998, pp.21-23.
[7] Ilmarinen. J, Aging workers, Occupational & Environmental Medicine, Vol.58, Issue 8, 2001, pp.546-552.
[8] Kondo. M, Working-hours management for prevention of heat disorders in workplaces at high temperature, Journal of working environment, Vol.29, No.4, 2008, pp. 62-70.
[9] Shishime. T, Promoting countermeasures on urban heat island towards low carbon society, Environmental & sanitary engineering research, Vol.22, No.3, 2008, pp. 195-198.
[10] Ministry of Health, Labour and Welfare “Heat stroke prevention leaflet” http://www.mhlw.go.jp/stf/houdou/2r9852000002btf0-att/2r9852000002btgh.pdf(27/9/2014)
[11] FY 2008 Annual Energy Report (outline) (2009, Aug). Agency for Natural Resources and Energy (ANRE) [Online]. Available: http://www.enecho.meti.go.jp/english/report/outline.pdf.
[12] Global Environment Global Environment News Headline. The FY 2008 Annual Report on Ozone Layer Monitoring (2009, Sep 14). Ministry of the Environment Government [Online]. Available: http://www.env.go.jp/en/headline/headline.php.
[13] Takashi Oda, Masato Tazawa, Takeshi Kunishima and Kimihiro Yamanaka, Effect of Penetration Depth of Far-infrared Radiation into Architectural Wall, Proc. of Grand Renewable Energy 2014 International Conference and Exhibition, (accepted).
Cite This Article
  • APA Style

    Takashi Oda, Kimihiro Yamanaka, Mitsuyuki Kawakami. (2014). Case Study of The Relationship between Heat-Resistant Paint and Comfortable Indoor Temperatures. International Journal of Environmental Protection and Policy, 2(5), 185-189. https://doi.org/10.11648/j.ijepp.20140205.17

    Copy | Download

    ACS Style

    Takashi Oda; Kimihiro Yamanaka; Mitsuyuki Kawakami. Case Study of The Relationship between Heat-Resistant Paint and Comfortable Indoor Temperatures. Int. J. Environ. Prot. Policy 2014, 2(5), 185-189. doi: 10.11648/j.ijepp.20140205.17

    Copy | Download

    AMA Style

    Takashi Oda, Kimihiro Yamanaka, Mitsuyuki Kawakami. Case Study of The Relationship between Heat-Resistant Paint and Comfortable Indoor Temperatures. Int J Environ Prot Policy. 2014;2(5):185-189. doi: 10.11648/j.ijepp.20140205.17

    Copy | Download

  • @article{10.11648/j.ijepp.20140205.17,
      author = {Takashi Oda and Kimihiro Yamanaka and Mitsuyuki Kawakami},
      title = {Case Study of The Relationship between Heat-Resistant Paint and Comfortable Indoor Temperatures},
      journal = {International Journal of Environmental Protection and Policy},
      volume = {2},
      number = {5},
      pages = {185-189},
      doi = {10.11648/j.ijepp.20140205.17},
      url = {https://doi.org/10.11648/j.ijepp.20140205.17},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijepp.20140205.17},
      abstract = {Higher temperatures can cause health problems such as heat stroke, and the number of cases increases sharply in people over 65 years old. Elderly people have a high risk of heat stroke, not only during the day but also at night, and they also have a reduced sensitivity to heat, so the possibility that countermeasures are taken too late increases. In such cases adverse effects cannot be prevented by measures involving voluntary action, including the provision of air conditioning. For these reasons, heat stroke countermeasures involving methods that do not depend on the sensory functions of the target person are needed. Therefore, we propose a new method for controlling indoor temperatures using heat-resistant paint. In this study, two verification experiments were conducted totest the proposed temperature control method in cargo containers and communal buildings. The effectiveness of the methods was apparent in measurements of temperature and electricity consumption.},
     year = {2014}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Case Study of The Relationship between Heat-Resistant Paint and Comfortable Indoor Temperatures
    AU  - Takashi Oda
    AU  - Kimihiro Yamanaka
    AU  - Mitsuyuki Kawakami
    Y1  - 2014/10/20
    PY  - 2014
    N1  - https://doi.org/10.11648/j.ijepp.20140205.17
    DO  - 10.11648/j.ijepp.20140205.17
    T2  - International Journal of Environmental Protection and Policy
    JF  - International Journal of Environmental Protection and Policy
    JO  - International Journal of Environmental Protection and Policy
    SP  - 185
    EP  - 189
    PB  - Science Publishing Group
    SN  - 2330-7536
    UR  - https://doi.org/10.11648/j.ijepp.20140205.17
    AB  - Higher temperatures can cause health problems such as heat stroke, and the number of cases increases sharply in people over 65 years old. Elderly people have a high risk of heat stroke, not only during the day but also at night, and they also have a reduced sensitivity to heat, so the possibility that countermeasures are taken too late increases. In such cases adverse effects cannot be prevented by measures involving voluntary action, including the provision of air conditioning. For these reasons, heat stroke countermeasures involving methods that do not depend on the sensory functions of the target person are needed. Therefore, we propose a new method for controlling indoor temperatures using heat-resistant paint. In this study, two verification experiments were conducted totest the proposed temperature control method in cargo containers and communal buildings. The effectiveness of the methods was apparent in measurements of temperature and electricity consumption.
    VL  - 2
    IS  - 5
    ER  - 

    Copy | Download

Author Information
  • System Design of Tokyo Metropolitan University, Tokyo, Japan

  • System Design of Tokyo Metropolitan University, Tokyo, Japan

  • Human Sciences of Kanagawa University, Kanagawa, Japan

  • Sections